CWW-TB150 Window Wall (Thermal Insulation)

CWW-TB150 Window Wall (Thermal Insulation)

Window wall CWW-N15 is a system in great performance of thermal insulation, with high energy efficient thermal break aluminum profile mullions and transoms. It totally offers quality constructions in affordable prices and fully meets all stability and safety requirements.

  • Overview
  • Data
  • Benefit
  • Configuration

Overview of CWW-TB150 Window Wall

SystemWindow Wall(Thermal Break)
Model No.CWW-TB150
MaterialAluminum Alloy/Glass/Aluminum Sheet/Aluminum Composite Panel/Galvanized Sheet
HardwareChinese top brand(Kin Long)/Germany brand
Glass TypeTempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak
Cooperated Glass BrandVitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/Kibing/CNG/TaiwanGlass
Surface TreatmentPowder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain
Profile Brand6063-T5/6063-T6/6061-T5/6061-T6
Themral ProfileNon-Thermal Break/Thermal Break
StandardsIn Complianca With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO
ApplicationResidential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization
System CustomziationAvailable


Data of CWW-TB150 Window Wall

Testing Data of CWW-TB150 Window Wall

Design Wind PressureWsls=+1.61KPA/-2.09KAP, Wuls=+2.49KPA/-3.23KPA
TestPressureResults
Preloading(Clause 8.2.2 of AS/NZS4284:2008)+1.61kpaNo separation, plastic deformations or deleterious was observed.
-2.09kpa
Preliminary Water Penetration Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284:2008)+482kPaThere were no leaks.
Preliminary Water Penetration Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284:2008)241-482-241 (Pa)There were no leaks.
321-642-321 (Pa)
482-964-482 (Pa)
Structural Test at Serviceability Limit State Wind Pressure (Wsls)(Clause 8.3 of AS/NZS 4284:2008)+1.61kpaDuring the structural test at SLS wind pressure, the deflections of all related members were within the allowable deflection limits.
-2.09kpa
Air Infiltration Test (Clause 8.4 of AS/NZS 4284:2008)+/-165PaThe rate of air leakage of the specimen was within the allowable values.
Water Penetration Test under Static Water Penetration Test under Static 4284:2008)+482PaThere were no leaks.
Water Penetration Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284:2008)241-482-241 (Pa)There were no leaks.
321-642-321 (Pa)
482-964-482 (Pa)
Structural ProofTest at Ultimate Limit State Wind Pressure (Wuls) (Clause 8.8 of AS/NZS 4284:2008)+2.49kpaNo collapse of the test specimen was observed under the specified pressure.
-3.23kpa
Seal Degradation Test(Clause 8.10 of AS/NZS 4284:2008)241-482-241 (Pa)No water leakage was observed.
321-642-321 (Pa)
482-964-482 (Pa)


Thermal Data of CWW-TB150 Window Wall

NFRC ProceduresNFRC100SB, NFRC200-2010 and NFRC500-2010
Software ToolsTHERM 7.4.3.0 and WINDOW 7.4.6.0
Configuration6mm HS (CAVS S1)#2 +12Ar +6-T-HST
Panel Dimension2640mm Wide 6890mm High
FramePainted Aluminum
Panel U-value2.293W/m2k
Visible Light Transmission0.69
SHGC0.547


Frame Data of CWW-TB150 Window Wall

Parts LocationFrame Area/m2Edge Area/m2U-Value(Frame)
W/m2k
U-Value(Edge)
W/m2k
Header0.04500.064011.10561.9779
Left Jamb0.10400.15806.86341.8595
Right Jamb0.10400.15806.87711.8573
Sill0.05000.064012.77281.9112


Glass Data of CWW-TB150 Window Wall

Glass Data: mm HS (CAVS S1)#2 +12Ar +6-T-HST
Visible LightSHGCSCNFRC U-value
W/m3k(Argon)
STC
T%R-out%R-in%WinterSummer
7212120.550.631.551.5436


Benefit of CWW-TB150 Window Wall

  • High Energy Efficiency

  • Enhancement of Natural Light

  • Being up to complicated facade design requirements

  • Faster installation speed

  • A expanded view for daily routine

  • Ability to design custom solutions tailor made to the building

  • Minimum after sales service & maintaining

  • Increased comfort level