CHD-TB85HT Hinged Door (Thermal Break)
Hinged door CHD-TB85HT, is a similar double hinged door system to CHD-TB85. Due to its specially designed profiles, profiles can be hidden underground and make a flat surface. Owning a great performance in thermal insulation with its thermal profiles, it also offers a reliable waterproof and water draining ability.
- Overview
- Data
- Benefit
- Configuration
Overview of CHD-TB85HT Hinged Door (Thermal Break)
System | Swing Door (Thermal Break) |
Model No. | CHD-TB85HT |
Material | Aluminum Alloy/Glass |
Hardware | Chinese top brand(Kin Long)/Germany brand |
Glass Type | Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak |
Cooperated Glass Brand | Vitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/Kibing/CNG/TaiwanGlass |
Surface Treatment | Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain |
Profile Brand | 6063-T5/6063-T6 |
Thermal Profile | Thermal Break |
Standards | In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO |
Application | Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization |
System Customization | Available |
Data of CHD-TB85HT Hinged Door (Thermal Break)
Testing Data of CHD-TB85HT Hinged Door (Thermal Break)
Test | Pressure | Results |
Open and Close Operable Sash Test (AS 2047-2014 & AS/NZS 4420.1-2016) | -- | No damage was observed after the test. |
Preloading (AS 2047-2014 & AS/NZS 4420.1-2016) | +0.81kPa -0.85kPa | No separation, plastic deformations or deleterious was observed. |
Structural Test at Serviceability Limit State Wind Pressure (Wsls) (AS2047-2014 & AS/NZS 4420.1-2016) | +1.62kPa -1.62kPa | No glass breakage, collapse and permanent deformation was observed. Deflections of mullions and transomes as well as glass panel were within the allowable deflection limits. |
Operating Force Test (AS 2047-2014 & AS/NZS 4420.1-2016) | -- | The operating force of the specimen was within the allowable value. |
Air Infiltration Test (AS 2047-2014 & AS/NZS 4420.1-2016) | +150Pa -150Pa | The rate of air leakage of the specimen was within the allowable values. |
Water Penetration Test under Static Pressure (AS 2047-2014 & AS/NZS 4420. 1-2016) | +486Pa | No water leakage was observed. |
Structural Proof Test at Ultimate Limit State Wind Pressure (Wuls) (AS 2047-2014 & AS/NZS 4420.1-2016) | +2.50kpa -2.60kpa | There was no collapse of the test sample. |
Thermal Data of CHD-TB85HT Hinged Door (Thermal Break)
NFRC Procedures | NFRC100SB, NFRC200-2010 and NFRC500-2010 |
Software Tools | THERM 7.4.3.0 and WINDOW 7.4.6.0 |
Configuration | 6 single silver Low-E CAVS S1 on Clear #2 + 12Ar + 5/1.52PVB/5 Clear |
Panel Dimension | 2000mm Wide 2440mm High |
Frame | Painted Aluminum |
Panel U-value | 3.481W/m2k |
Visible Light Transmission | 0.45 |
SHGC | 0.376 |
Condensation Resistant | 30.5 |
Frame Data of CHD-TB85HT Hinged Door (Thermal Break)
Parts Location | Frame Area/m2 | Edge Area/m2 | U-Value(Frame) W/m2k | U-Value(Edge) W/m2k |
Left Header | 0.1910 | 0.0420 | 6.1182 | 2.1869 |
Left Jamb | 0.4750 | 0.1300 | 6.0585 | 2.1841 |
Right Header | 0.1910 | 0.0420 | 6.1182 | 2.1869 |
Mullion | 0.3980 | 0.2530 | 4.8335 | 2.1265 |
Right Jamb | 0.4750 | 0.1300 | 6.1144 | 2.1880 |
Left Sill | 0.0990 | 0.0420 | 10.0888 | 2.2422 |
Right Sill | 0.0990 | 0.0420 | 10.0888 | 2.2422 |
Glass Data of CHD-TB85HT Hinged Door (Thermal Break)
Glass Data: 6mm HS (CAVS S1)#2 +12Ar +6-T-HST | |||||||
Visible Light | SHGC | SC | NFRC U-value W/m3k(Argon) | STC | |||
T% | R-out% | R-in% | Winter | Summer | |||
72 | 12 | 12 | 0.55 | 0.63 | 1.55 | 1.54 | 36 |
Benefits of CHD-TB85HT Hinged Door (Thermal Break)
Hidden aluminum profiles
Great performance in waterproofness and water draining
High energy savings due to the high energy efficiency of the system
High level of sound insulation
Modern design
High quality with certified performances
Increased static loads and functionality in case of severe weather conditions
Entrance doors with ease of access according to specifications for people with special needs