Email
CFD-N64 Folding Door

CFD-N64 Folding Door

Similar with model CFD-N101, CFD-N64 is a top-hung operation folding door system with bottom wheels. Compare to CFD-N101, CFD-N64 have a slimmer outer frame to adapt with different installation condition, but still keep the same performance.     

  • Overview
  • Data
  • Benefit
  • Configuration

Overview of CFD-N64 Folding Door

SystemFolding Door(Non-Thermal Break)
Model No.CFD-N64
MaterialAluminum Alloy/Glass
HardwareChinese top brand(Kin Long)/Germany brand
Glass TypeTempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak
Cooperated Glass BrandVitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/Kibing/CNG/TaiwanGlass
Surface TreatmentPowder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain
Profile Brand6063-T5/6063-T6
Thermal ProfileNon-Thermal Break
StandardsIn Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO
ApplicationResidential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization
System CustomisationAvailable


Data of CFD-N64 Folding Door

Testing Data of CFD-N64 Folding Door

TestPressureResults
Preloading(Clause 8.2.2 of AS/NZS4284:2008)+1.81kpa
-2.68kpa
No separation, plastic deformations or deleterious was observed.
Preliminary Water Penetration Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284:2008)+543kPaThere were no leaks.
Preliminary Water Penetration Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284:2008)272-300-272 (Pa)
362-724-362 (Pa)
543-1086-543 (Pa)
There were no leaks.
Structural Test at Serviceability Limit State Wind Pressure (Wsls)(Clause 8.3 of AS/NZS 4284:2008)+1.81kpa
-2.68kpa
No glass breakage, no collapse and permanent deformation were observed. Deflections of mullions and transoms as well as glass panel were within the allowable deflection limits.
Air Infiltration Test (Clause 8.4 of AS/NZS 4284:2008)+/-150PaThe rate of air leakage of the specimen was within the allowable values.
Operating force test (AS 2047-2014, Clause 2.3.2.4)--The operating force of the specimen was within allowable value.
Water Penetration Test under Static Water Penetration Test under Static 4284:2008)+543PaThere were no leaks.
Water Penetration Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284:2008)272-300-272 (Pa)
362-724-362 (Pa)
543-1086-543 (Pa)
There were no leaks.
Structural Proof Test at Ultimate Limit State Wind Pressure (Wuls) (Clause 8.8 of AS/NZS 4284:2008)+2.79kpa
-4.15kpa
No collapse of the test specimen was observed under the specified pressure.


Thermal Data of CFD-N64 Folding Door

NFRC ProceduresNFRC100SB, NFRC200-2010 and NFRC500-2010
Software ToolsTHERM 7.4.3.0 and WINDOW 7.4.6.0
Configuration6mm LB13-45HS+12A+6mm Clear HST
Panel Dimension4000mm Wide x 2750mm High
FramePainted Aluminum
Panel U-value3.983W/m2k
Visible Light Transmission0.286
Condensation Resistant19.2


Frame Data of CFD-N64 Folding Door

Parts LocationFrame Area/m2Edge Area/m2U-Value(Frame)
W/m2k
U-Value(Edge)
W/m2k
Header0.12100.05786.32821.1017
Left Jamb0.10220.04948.89380.9748
Mullion0.21100.023218.10030.5393
Right Jamb0.10220.04947.03301.0273
Bottom0.11300.05329.17451.0345


Glass Data of CFD-N64 Folding Door

Glass Data: 6mm LB13-45HS+12A+6mm Clear HST
Visible LightSHGCSCNFRC U-value
W/m3k(Argon)
STC
T%R-out%R-in%WinterSummer
402013
0.261.431.3636


Benefits of CFD-N64 Folding Door

  •  Smooth operation

  •  Slimmer track profiles, better visual effect

  •  A wider view with minimal space occupation

  •  Sturdy structure with the flawless and long-lasting operation

  •  Large dimensions and wide spans

  •  High performance in terms of wind resistance, air permeability, and water tightness

  • Easy machining and installation


Configuration of CFD-N64 Folding Door

Blog

Contact Us

Welcome your presence, you can send us an email, we will get in touch with you within 24 hours.